--| --|Item: Ada PCTE Binding --|$Revision: 0.2 $ --|$State: Prototype $ --| --|The Version Description Document (VDD) included with this release provides --|detailed information regarding the condition of the software. The "User --|Feedback" section of the VDD describes how to obtain additional information. --| --|Distribution Statement "A", per DoD Directive 5230.24 --|Authorized for public release; distribution is unlimited. --| --|Copyright (c) 1992, Paramax Systems Corporation, Reston, Virginia --|Copyright is assigned to the U.S. Government, upon delivery thereto, --|in accordance with the DFAR Special Works Clause. --| --|Developed by: Paramax Systems Corporation, --| --|This software, developed under the Software Technology for Adaptable, --|Reliable Systems (STARS) program, is approved for release under --|Distribution "A" of the Scientific and Technical Information Program --|Classification Scheme (DoD Directive 5230.24) unless otherwise indicated. --|Sponsored by the U.S. Defense Advanced Research Projects Agency (DARPA) --|under contract F19628-88-D-0031, the STARS program is supported by the --|military services, SEI, and MITRE, with the U.S. Air Force as the executive --|contracting agent. --| --|Permission to use, copy, modify, and comment on this software and its --|documentation for purposes stated under Distribution "A" and without fee --|is hereby granted, provided that this notice appears in each whole or --|partial copy. This software retains Contractor indemnification to --|the Government regarding copyrights pursuant to the above referenced --|STARS contract. The Government disclaims all responsibility against --|liability, including costs and expenses for violation of proprietary --|rights, or copyrights arising out of the creation or use of this --|software. --| --|In addition, the Government, Paramax, and its subcontractors disclaim all --|warranties with regard to this software, including all implied warranties --|of merchantability and fitness, and in no event shall the Government, --|Paramax, or its subcontractor(s) be liable for any special, indirect or --|consequential damages or any damages whatsoever resulting from the loss of --|use, data, or profits, whether in action of contract, negligence or other --|tortious action, arising in connection with the use or performance of this --|software. --| --|$Log $ --| -- Version Information -- ^^^^^^^^^^^^^^^^^^^ -- -- PCTE - Ada Language Interface. -- Version: 0.2. -- Release Date: November 30, 1992. -- Compiled under SUN OS 4.1.2 using SunAda 1.0 -- -- -- General Information -- ^^^^^^^^^^^^^^^^^^^ -- -- This is an alpha release of the Paramax STARS Ada binding to Emeraude's -- PCTE 1.5 using the ECMA PCTE Ada binding specifications. The binding -- is incomplete in this release. See the Version Description Document -- provided with this alpha release for information on which interfaces -- have been implemented. It is expected that future releases will -- expand the number of interfaces implemented. The interfaces defined -- herein are subject to change. -- -- For further information, contact the authors: -- -- -- Robert Smith -- Paramax Systems Corp. -- Valley Forge Labs -- 70 E. Swedesford Road -- Paoli, PA. 19301 -- smith@prc.unisys.com (current) -- smith@vfl.paramax.com (future) -- +1 215 648-2402 -- -- Michael Horton -- Paramax Systems Corp. -- Valley Forge Labs -- 70 E. Swedesford Road -- Paoli, PA. 19301 -- horton@prc.unisys.com (current) -- horton@vfl.paramax.com (future) -- +1 215 648-2527 -- -- --% NOTE: This package will not be supported by Ada binding to PCTE 1.5 with Pcte, Pcte_error, Pcte_discretionary; package Pcte_workstation is use Pcte, Pcte_error, Pcte.reference; type connection_status is (LOCAL, CLIENT, AVAILABLE, CONNECTED); -- Pcte_workstation.connection_status corresponds -- to the PCTE datatype Connection_status. type work_status_item is ( ACTIVITY_REMOTE_LOCKS, ACTIVITY_LOCAL_LOCKS, TRANSACTION_REMOTE_LOCKS, TRANSACTION_LOCAL_LOCKS, QUEUE_REMOTE, QUEUE_LOCAL, RECEIVE_REMOTE, RECEIVE_LOCAL, CHILD_REMOTE, CHILD_LOCAL); -- Pcte_workstation.work_status_item corresponds -- to the PCTE datatype Work_status_item. type work_status is array (work_status_item) of Pcte.boolean; -- Pcte_workstation.work_status corresponds to the PCTE datatype Work_status. -- 18.2.1 WORKSTATION_CHANGE_CONNECTION procedure change_connection ( pcte_status : in Pcte_workstation.connection_status; force : in Pcte.boolean; station : in Pcte.object_reference := LOCAL_WORKSTATION; status : in Pcte_error.handle := EXCEPTION_ONLY); -- The effect of not providing the optional parameter station is obtained by -- specifying station as the default value LOCAL_WORKSTATION. -- The parameter force is a boolean of value TRUE for FORCE -- and FALSE for GENTLE. -- 18.2.2 WORKSTATION_CONNECT procedure connect ( pcte_status : in Pcte_workstation.connection_status; status : in Pcte_error.handle := EXCEPTION_ONLY); -- 18.2.3 WORKSTATION_CREATE -- The effect of providing the optional parameter -- existing_administration_volume is obtained by the first -- overloaded procedure; in that case the optional parameters foreign_device , -- new_administration_volume , and new_device are not needed. -- The effect of not providing existing_administration_volume is -- obtained by the second overloaded procedure. procedure create ( execution_site_identifier : in Pcte.natural; existing_administration_volume : in Pcte.object_reference; access_mask : in Pcte_discretionary.object.access_rights; other_parameter : in Pcte.string; status : in Pcte_error.handle := EXCEPTION_ONLY); procedure create ( execution_site_identifier : in Pcte.natural; access_mask : in Pcte_discretionary.object.access_rights; foreign_device : in Pcte.string; new_administration_volume : in Pcte.natural; new_device : in Pcte.natural; other_parameter : in Pcte.string; status : in Pcte_error.handle := EXCEPTION_ONLY); -- 18.2.4 WORKSTATION_DELETE procedure delete ( station : in Pcte.object_reference; status : in Pcte_error.handle := EXCEPTION_ONLY); -- 18.2.5 WORKSTATION_DISCONNECT procedure disconnect ( status : in Pcte_error.handle := EXCEPTION_ONLY); -- 18.2.6 WORKSTATION_STATUS procedure status ( connection : out Pcte_workstation.connection_status; work : out Pcte_workstation.work_status; station : in Pcte.object_reference := LOCAL_WORKSTATION; status : in Pcte_error.handle := EXCEPTION_ONLY); -- The effect of not providing the optional parameter station -- is obtained by specifying station as the default value LOCAL_WORKSTATION. end Pcte_workstation; -- 18.3.1 CONTENTS_COPY_FROM_FOREIGN_SYSTEM -- See 12.2. -- 18.3.2 CONTENTS_COPY_TO_FOREIGN_SYSTEM -- See 12.2.